<LOGO>
FM Transmitter Measurement Report
Created: 2024-12-29 12-45-20
Measuring equipment: P75/P175/P275
http://pira.cz
Station Details
Frequency Signal Reception Station Name
94.70 MHz 5/5, 59 dBuV SANDELS
Pilot RDS Phase Difference
6.3 kHz 5.9 kHz No phase relation found.
Frequency Deviation
Limit Measuring Tolerance
75,0 kHz 1,0 kHz
MIN Hold Max. Samples at Total Samples % above 76,0 kHz
12 kHz 64 kHz 15340 8,2529
Modulation Power
Limit Measuring Tolerance
12,0 dBr 0,2 dBr
MIN AVE MAX % above 12,2 dBr
2,0 dBr 3,97 dBr 5,1 dBr 0,0
Radio Data System
PS PI PTY TP TA  MS   DI   CT 
"SANDELS " 61F1 9 (Varied) 1 0 1 13 --:--
RT
-
AF EON
94.7 MHz -
FM Scope Max at: 64 kHz MIN: 12 kHz % above 76 kHz: 8,2529 Acquired: 2024/12/29 12.44.16 Total samples: 15340 Equivalent time: 0:12:47 0 10 20 30 40 50 60 70 80 90 100 110 120 Frequency Deviation [kHz] 0 200 400 600
FM Scope MAX: 5,1 dBr MIN: 2,0 dBr AVE: 3,97 dBr % above 12,2 dBr: 0,0 Last value: 4,8 dBr (2024/12/29 12.44.16) 12.30 12.32 12.34 12.36 12.38 12.40 12.42 12.44 0 2 4 6 Pm [dBr]